ACCUSPIN™ Tubes by Merck — Optimized Cell Separation for Research and Diagnostics

Efficient isolation of lymphocytes and mononuclear cells is crucial for cell-based research, diagnostics, and pharmaceutical applications. The ACCUSPIN™ Tubes with Histopaque®-1077 offer a sterile and precise solution for blood sample separation, addressing challenges with sample integrity and recovery. Discover how ACCUSPIN™ Tubes simplify cell separation while maximizing purity and efficiency.
Why Choose ACCUSPIN™ Tubes
- Clear mononuclear cell isolation: Enables clear separation of lymphocytes and other mononuclear cells, including monocytes, from whole blood and bone marrow when used with Histopaque®-1077.
- Reduced erythrocyte contamination: Helps avoid erythrocyte contamination during collection of the mononuclear cell band.
- Support for immunology workflows: Suitable for human lymphocyte antigen typing and as an initial isolation step prior to enumeration of T, B, and null lymphocytes.
- Prepared cells for research use: Supports preparation of pure lymphocyte suspensions for cell culture and cytotoxicity assays.
- Broad downstream compatibility: Isolated cells can be used for characterization, culture, analysis, flow cytometry, cell-based assays, molecular analysis, pharmaceutical development, or cell therapy development.
- Reliable sample processing outcomes: Produces the expected distribution in which erythrocytes and granulocytes pellet while mononuclear cells remain at the interface for collection.
Key Features and Design of ACCUSPIN™ Tubes
- Tube Format: Polypropylene centrifuge tube architecture configured for use with density gradient separation medium Histopaque®-1077.
- Chamber design: Two-chamber construction physically separates the upper and lower sections of the tube during centrifugation.
- Barrier component: A porous high-density polyethylene frit is positioned between the two chambers to maintain a stable separation layer.
- Sterility Configuration: Radiation sterilized polypropylene tube assembly fitted with a high-density polyethylene frit.
- System Pairing: ACCUSPIN™ Tubes are intended for use with Histopaque®-1077 in the isolation of lymphocytes and other mononuclear cells.
Technical Specifications for ACCUSPIN™ Tubes
- Tube capacities: 12 mL and 50 mL
- Catalog numbers: A1805 for 12 mL capacity and A2055 for 50 mL capacity
- Pack sizes: 20 each for 12 mL capacity and 10 each for 50 mL capacity
- Tube material: Polypropylene
- Barrier material: Porous high density polyethylene frit
- Sterilization status: Radiation sterilized
- Storage condition: Room temperature
- Compatible separation medium: Histopaque®-1077
- Required Histopaque®-1077 volume: 3 mL for 12 mL ACCUSPIN™ Tubes and 15 mL for 50 mL ACCUSPIN™ Tubes
- Initial centrifugation step: 800 × g for 30 seconds at room temperature
- Blood sample volume: 3 to 6 mL for 12 mL ACCUSPIN™ Tubes and 15 to 30 mL for 50 mL ACCUSPIN™ Tubes
- Specimen type and anticoagulant: Blood collected in preservative-free EDTA or heparin, or defibrinated blood
- Recommended processing time for blood: Within 2 hours
- Optional sample dilution: 3 to 5-fold, depending on absolute cell numbers
- Main separation centrifugation: 1,000 × g for 10 minutes at room temperature
- Alternative separation centrifugation: 800 × g for 15 minutes at room temperature
- Centrifuge requirement: Swinging bucket rotor capable of generating 1,000 × g
- Plasma aspiration point: To within 0.5 cm of the opaque interface
- First wash volume: 10 mL of isotonic phosphate buffered saline solution or appropriate cell culture medium
- Wash centrifugation: 250 × g for 10 minutes at room temperature
- Resuspension volume after first wash: 5 mL of isotonic phosphate buffered saline solution or appropriate cell culture medium
- Final resuspension volume: 0.5 mL of isotonic phosphate buffered saline solution or appropriate cell culture medium
- Optional platelet removal condition: Second centrifugation in a 4% sucrose gradient layered over Histopaque®-1077
Applications and Typical Use of ACCUSPIN™ Tubes
- Isolation of lymphocytes and other mononuclear cells: ACCUSPIN™ Tubes are intended for use with Histopaque®-1077 in the isolation of lymphocytes and other mononuclear cells from whole blood and bone marrow.
- High level workflow: After Histopaque®-1077 is placed below the barrier in the ACCUSPIN™ Tube by centrifugation, the blood sample is added to the upper chamber, and subsequent centrifugation separates blood components so that lymphocytes and other mononuclear cells remain at the plasma/Histopaque®-1077 interface for collection.
- HLA typing: Histopaque®-1077 used with ACCUSPIN™ Tubes is suitable for human lymphocyte antigen typing.
- Lymphocyte population studies: The system can be used as the initial isolation step prior to enumeration of T, B, and null lymphocytes.
- Cell culture and cytotoxicity assays: It may be employed in the preparation of pure lymphocyte suspensions for cell culture and cytotoxicity assays.
- Downstream research and analytical use: Isolated cells can be used for downstream characterization, flow cytometry, cell-based assays, and molecular analysis.
- Pharmaceutical and cell therapy development: The separated cells are suitable for pharmaceutical and cell therapy development.
ACCUSPIN™ Tubes Product Options
| Product | Capacity | Pack Size |
|---|---|---|
| ACCUSPIN™ Tubes | 50 mL | 10 each |
| ACCUSPIN™ Tubes | 12 mL | 20 each |
Chemical Express, with over 23 years of expertise and as the official distributor of Merck in Thailand, offers ACCUSPIN™ Tubes and other Merck cell separation products for your research and diagnostics needs. Purchase ACCUSPIN™ Tubes and related solutions from trusted brands through Chemical Express for consistent product quality and professional technical support.
Have questions about ACCUSPIN™ Tubes or ready to order?
Simply fill out our Inquiry Form or chat with us instantly on Line using the buttons below.
We’re here to help!