Ascentis® Express F5 (Pentafluorophenyl, PFP) by Merck – Enhanced Selectivity HPLC Column for Isomer & Compound Separation

Approx.4 min readByChemical Express

The Ascentis® Express F5 (pentafluorophenyl, PFP) HPLC column features a pentafluorophenylpropyl stationary phase providing enhanced selectivity for structural isomers and closely related compounds, with suitability for basic, acidic, or neutral analytes and orthogonal selectivity to C18.

Benefits of Ascentis® Express F5 (Pentafluorophenyl, PFP) HPLC Column

  • Enhanced selectivity for structural isomers and closely related compounds: Provides selectivity for structural isomers and closely related compounds where conventional non-polar phases such as C18 are often ineffective.
  • Selectivity for compounds with similar solubility: Chromatographers are often faced with the challenge of separating compounds that are very similar in solubility; separation on non-polar phases such as C18 is driven by differential partitioning of analytes, and alkyl phases are often ineffective in meeting this challenge. The F5 phase offers an alternative selectivity for such separations.
  • Orthogonal selectivity to C18: Provides an alternative retention mechanism that is orthogonal to C18 columns.
  • Longer retention of basic analytes compared to C18: The F5 phase retains basic analytes more strongly than C18, reducing co-elution risks in complex matrices and improving peak resolution for amine-containing compounds.
  • Reduced retention of hydrophobic analytes versus C18: Highly hydrophobic analytes elute faster on the F5 phase than on C18, enabling shorter run times and more practical gradient conditions for lipophilic compounds.
  • Broad compound compatibility: The F5 phase accommodates basic, acidic, and neutral analytes within a single method platform, reducing the need for dedicated columns across different compound classes.
  • Stable, low bleed for LC-MS and LC-UV: The column’s low-bleed construction minimises background noise in mass spectrometry workflows and ensures clean baseline performance in UV-based detection.

Features of Ascentis® Express F5 (Pentafluorophenyl, PFP) HPLC Column

  • Stationary Phase Composition: Pentafluorophenylpropylsilane phase chemistry, with a pentafluorophenylpropyl group covalently bonded to the silica surface.
  • Electron-Deficient Phenyl Rings: The presence of electronegative fluorines on the phenyl ring creates electron-deficient phenyl rings, contributing to the phase’s distinct retention and selectivity characteristics.
  • Interaction Mechanisms: These combined pi-pi, polar, and mildly steric interactions are the chemical basis for the column’s orthogonal selectivity advantage over C18 described above.
  • Dual-Mode Retention Behavior: As a result of having both polar and non-polar character, the F5 phase can show dual-mode retention behavior, sometimes producing a “U-shaped” retention as a function of acetonitrile content of the mobile phase, with retention increasing at both low and high concentrations of ACN (reversed-phase and HILIC retention modes).
  • Silica Base Material: Type B high purity silica, which forms the structural foundation of the packing material.
  • Particle Platform: Superficially porous particles (SPP).
  • Available Particle Sizes: Offered in 2.0 µm and 2.7 µm particle size formats.

Ascentis® Express F5 PFP Column – Technical Specifications

Ascentis® Express F5 Specifications
Silica:Type B (High purity silica)
Particle Platform:Superficially porous particles (SPP)
Phase Chemistry:pentafluorophenylpropylsilane
Particle Size:2.0 µm / 2.7 µm / 5.0 µm
Pore Size:90 Å
Carbon Load:5.3% / 5.5% / 3.9%
Surface Area:120 m²/g / 135 m²/g / 90 m²/g
pH Range:2 – 9
Max Temperature at Low pH:60 °C
Max Temperature at High pH:40 °C
Endcapped:Yes

Applications of Ascentis® Express F5 (Pentafluorophenyl, PFP) HPLC Column

  • Structural Isomer and Closely Related Compound Separation: Can be used for the separation of structural isomers and closely related compounds.
  • Separations Where C18 Is Often Ineffective: Applied to cases where compounds are very similar in solubility and separation on non-polar alkyl phases such as C18 is often ineffective.
  • Reversed-Phase Applications: Suitable for reversed-phase applications.
  • HILIC Applications: Suitable for HILIC applications, taking advantage of the column’s dual-mode retention behavior.
  • 100% Aqueous Applications: Suitable for 100% aqueous applications.

With over 23 years of expertise, Chemical Express serves as the official distributor of Merck in Thailand, offering access to the Ascentis® Express F5 and a full range of Merck chromatography solutions. Discover and purchase innovative products to support your analytical chromatography needs directly through Chemical Express.

Have questions about Ascentis® Express F5 (pentafluorophenyl, PFP) or ready to order?

Simply fill out our Inquiry Form or chat with us instantly on Line using the buttons below.
We’re here to help!

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.