CellASIC® ONIX2 Microfluidic System by Merck – Advanced Live Cell Imaging & Precision Cell Culture for Cutting-Edge Research

Transform your cell imaging workflow with the CellASIC ONIX2 Microfluidic System by Merck (CellASIC® ONIX2). Scientific research increasingly demands dynamic, controllable environments and real-time insights into cellular processes. Traditional endpoint analyses often miss dynamic cellular changes. The ONIX2 system uses advanced microfluidic technology to automate precise control of cell culture conditions for continuous, high-magnification live cell imaging—empowering researchers to reveal biological details that are often missed with conventional methods.
Why Choose the CellASIC® ONIX2 Microfluidic System
- Precision environment control: Enables precise manipulation of key cell culture conditions so cellular responses can be measured under controlled and pre-programmed changes.
- Real-time cellular insight: Supports continuous, high magnification observation of live cells as they react to their environment in real time.
- Reproducible live cell experiments: Helps create a stable and reproducible environment for imaging over extended periods of time.
- Dynamic assay capability: Allows researchers to observe and measure cellular changes over time rather than relying only on endpoint analyses.
- Long-term cell health support: Promotes optimal cell health through continuous nutrient access and ongoing waste removal, including healthy long-term cultures outside the incubator.
- Rapid experimental changes: Enables rapid perturbations of environmental parameters, as well as fast and precise control over culture conditions.
- Parallel workflow efficiency: Provides the ability to run multiple independent experiments simultaneously.
- High-quality imaging consistency: Supports high-resolution live cell imaging while keeping cells in a single focal plane for tracking over time.
- Broad application flexibility: Supports dynamic assays on adherent and non-adherent cells across a wide range of live cell imaging applications.
- Microscope workflow enhancement: Expands the capabilities of an inverted microscope for long-term cell perfusion experiments and dynamic time-lapse analysis, building on the system’s automated control and compatibility features.
Core Features and System Components
- System Architecture: The CellASIC® ONIX2 Microfluidic System is an automated microfluidic platform for precise manipulation of key cell culture parameters during live cell imaging and microscopy.
- Controller System: The integrated microincubator controller maintains fluid movement, reagent additions, temperature conditions, and gas conditions.
- Microfluidic Plates: High-quality, optically clear microfluidic plates provide application-specific cell culture formats for live cell imaging.
- Culture Chambers: The plate assembly includes high optical clarity culture chambers designed for live-cell observation on an inverted microscope.
- Manifold Design: A low-profile manifold connects the control system with the microfluidic plates and mounts easily on an inverted microscope.
- Microscope Compatibility: The system integrates with a broad range of inverted microscopes and is compatible with any standard inverted microscope platform.
- Software: Intuitive software enables quick setup of detailed protocols for automated hands-free cell culture.
- Imaging Workflow Integration: The system works in conjunction with capture and analysis software used with the microscope.
- Automated Control Functions: The system automatically controls flow rates, gas shifts, temperature shifts, standing gradients, nutrient and drug additions, and media changes.
Technical Specifications
| General | |
|---|---|
| Dimensions | System: 330 mm wide × 306 mm deep × 108 mm high (13 in. × 12 in. × 4.25 in.) |
| Weight | System: 6.7 kg (14.75 lb) |
| Power consumption | 100–240 VAC, 50/60 Hz 40 W |
| Cooling mode | Air cooled (natural convection) |
| Environmental conditions | For indoor laboratory use |
| Operating temperature | 20°C to 30°C |
| Storage temperature | 5°C to 35°C |
| Stability of sample chamber temperature | ± 0.2°C |
| Rise time (25°C to 37°C) | < 30 minutes |
| Cooling time (37°C to 25°C) | < 30 minutes |
| Flow Control | |
| Number of outputs | 8 (each addressable by either of two pressure controllers) |
| Pressure range | -50 to 70 kPa (-7.25–10.2 psi) |
| Pressure accuracy | ± 1.5 kPa (0.22 psi) |
| Pressure stabilization time | within ± 5 kPa (0.73 psi) in < 5 seconds |
| Gas Environment Control | |
| Control capabilities | Option to electronically select between two premixed gasses and set flow rate to slow or fast |
| Gas input requirements | Clean, dry, premixed gas mixtures containing air, CO₂, N₂, and oxygen (up to 25%), regulated to between 100 kPa and 700 kPa (15 psi and 100 psi) |
| Gas consumption | Slow flow: 5 mL/min ± 2 mL/min |
| Gas consumption | Fast flow: 50 mL/min ± 20 mL/min |
| Cell culture region gas environment accuracy | For gas flow at 3 mL/min: < 10% deviation from delivered gas concentration |
| Cell culture region gas environment accuracy | For gas flow at 30 mL/min: < 2% deviation from delivered gas concentration |
| Temperature Control | |
| Temperature control range | Room temperature to 40°C |
| Control method | Bi-directional PID |
| Accuracy of sample chamber temperature | ± 1°C (using the CAX2-ACT20 ONIX2 Temperature Calibration Plate can result in accuracy as high as ± 0.2°C) |
| Computer Requirements | |
| Operating system | Windows® 7, or Windows® 10 (32 or 64 bit) |
| Random access memory (RAM) | 4 GB or higher |
| Monitor | 1920×1080 resolution or higher |
| Hard drive | 200 MB or higher |
| Hardware interface | USB 2.0 or higher |
| Microscope Requirements | |
| Type | Inverted microscope |
| Stage weight capacity | For CAX2-MXT20 CellASIC® ONIX2 Manifold XT and filled plate: 325 g (11.1 oz) |
| Stage weight capacity | For CAX2-MBC20 CellASIC® ONIX2 Manifold Basic and filled plate: 150 g (5.3 oz) |
| Minimum condenser working distance | For CAX2-MXT20 CellASIC® ONIX2 Manifold XT: 28 mm (0.9 in) |
| Minimum condenser working distance | For CAX2-MBC20 CellASIC® ONIX2 Manifold Basic: 28 mm (0.9 in) |
| Maximum condenser diameter | For CAX2-MXT20 CellASIC® ONIX2 Manifold XT: 70 mm (2.8 in) |
| Maximum condenser diameter | For CAX2-MBC20 CellASIC® ONIX2 Manifold Basic: no limit |
Applications and Use Cases
- Dynamic assays on adherent and non-adherent cells: The system is used to provide detailed information about live cell processes with ultra-high-quality images and complete environment control for dynamic assays on adherent and non-adherent cells.
- Yeast single cell response: It supports high-resolution imaging in a single focal plane with controlled nutrient flow for tracking single cells over time.
- Bacterial single cell response: The system can measure multi-generational responses while maintaining cells in a single focal plane for days.
- Bacterial biofilm dynamics: It enables continuous monitoring of community dynamics together with precise control of the growth environment.
- Long-term cell perfusion experiments and dynamic time-lapse analysis: In combination with an inverted microscope, the system maintains stable perfusion and environmental control for extended, high-resolution time-lapse studies.
- Cell response to hypoxic environments: Fast and precise control over culture conditions is used to induce hypoxic, starvation, or toxic microenvironments and observe cellular responses in real time.
- Cell response to changing media conditions, drugs and other stimulants: The system provides microfluidic control of nutrient additions during continuous observation and supports high-resolution imaging of dynamic cellular responses.
- Host-pathogen interactions: It is used for host-pathogen assay monitoring of cellular interactions during live cell imaging experiments.
- Chemotaxis/migration in response to chemogradient: Microfluidic control creates stable standing chemical gradients for observing chemotaxis and migration responses.
- Setting optimal culture parameters for difficult cell types or long-term experiments: Microfluidics and computer control allow quick adjustments to microenvironment parameters and media changes while cell behavior is recorded.
- Microscopy of 3D cell culture: Controlled perfusion and microenvironment management help create more in vivo-like conditions for complex 3D cultures during live-cell imaging.
Products Available Under the CellASIC® ONIX2 Microfluidic System
| Description | Qty |
|---|---|
| CellASIC® ONIX2 Microfluidic System and Manifolds | |
| CellASIC® ONIX2 Microfluidic System | 1 |
| CellASIC® ONIX2 Manifold XT (Temperature Controlled) | 1 |
| CellASIC® ONIX2 Manifold Basic (No Temperature Control) | 1 |
| Microfluidic Plates | |
| CellASIC® ONIX Plate for Haploid Yeast Cells | 5 |
| CellASIC® ONIX Plate for Diploid Yeast Cells | 5 |
| CellASIC® ONIX Plate for Bacteria Cells | 5 |
| CellASIC® ONIX Switching Plate for Mammalian Cells | 5 |
| CellASIC® ONIX Gradient Plate for Mammalian Cells | 5 |
| CellASIC® ONIX Open-Top Plate for Mammalian Cells | 5 |
| CellASIC® ONIX Plate for Chlamydomonas Cells | 5 |
Chemical Express, with over 23 years of expertise, is the official distributor of Merck in Thailand. Access the CellASIC® ONIX2 Microfluidic System and other related products from Merck’s reputable portfolio through Chemical Express, ensuring reliable distribution, expert support, and a comprehensive solution for your laboratory and research needs.
Have questions or ready to order the CellASIC® ONIX2 Microfluidic System?
Simply fill out our Inquiry Form or chat with us instantly on Line using the buttons below.
We’re here to help!