Watercol™ Capillary GC Columns from Supelco®: Advanced Moisture Analysis for Pharmaceuticals, Petrochemicals, and Environmental Applications

Precise moisture analysis is essential across pharmaceutical, environmental, and petrochemical industries. Traditional methods like Karl Fischer titration have limitations. Watercol™ Capillary GC Columns from Supelco® provide a practical, GC-based alternative. Utilizing advanced ionic liquid stationary phases, these columns deliver high accuracy, sensitivity, and efficiency for water analysis even in complex samples. Explore how Watercol™ columns address analytical challenges and streamline workflows.
Benefits of Watercol™ Capillary GC Columns
- Convenient water measurement by GC: Produces a sharp peak shape for water, enabling straightforward integration and quantification.
- Quantifiable performance: Supports a linear response for water with an r2 value of 0.9923.
- High sensitivity options: Achieves 100 ppm with TCD, less than 100 ppm with MSD or VUV, and less than 10 ppb with BID.
- Works when water is the target analyte: Enables separation of water from volatile organic compounds to support analysis of complex matrices.
- Works when water is the injection solvent: Avoids water tailing so water does not interfere chromatographically with other analytes.
- Supports small sample sizes: Delivers GC results using small sample amounts, including less than 2 mL gasoline and less than 0.2 g ibuprofen.
- Improved accuracy and speed vs. Karl Fischer titration: Reduces analysis time while maintaining high precision in moisture quantification.
- Higher sensitivity vs. Karl Fischer titration: Provides higher sensitivity in the 1 to 100 ppm range compared with moderate sensitivity of 5 to 500 ppm.
- Less hands-on workflow: Requires less hands-on time than Karl Fischer titration.
- Reduced method interferences: Minimizes unwanted side reactions and is less prone to interferences from organic compounds and acids than Karl Fischer titration.
- Lower chemical waste: Generates a lower volume of chemical waste than Karl Fischer titration.
- No solubility limitations: Avoids solubility issues that may be encountered with Karl Fischer titration.
- More information per run: Enables simultaneous analysis of water and volatile components, instead of limiting each run to water content only.
- Improved lab safety profile: Reduces worker exposure to harmful chemicals compared with Karl Fischer titration.
- Reliability for routine operation: Stability against water and thermal degradation supports dependable use for moisture analysis.
Features of Watercol™ Capillary GC Columns
- Product type: Watercol™ products are capillary GC columns developed by Supelco® Analytical Products (Merck KGaA, Darmstadt, Germany) for analytical chromatography.
- Stationary phase technology: Watercol™ capillary GC columns contain innovative ionic liquid stationary phases.
- Column family and designation: Watercol™ 1910 is a specialized ionic liquid column designed for gas chromatography.
- Phase format: Watercol™ 1910 uses a non-bonded stationary phase.
- Phase identity: The Watercol™ 1910 phase is 1,11-Di(3-hydroxyethylimidazolium) 3,6,9-trioxaundecane trifluoromethanesulfonate.
- Descriptive number meaning: The “1910” designation indicates the Kovats Retention Index (KRI) value of water at 100 °C under isothermal oven temperature.
- KRI reference basis: KRI values describe the elution location of an analyte relative to n-alkanes, where the n-alkane carbon number is multiplied by 100.
Technical Specifications for Watercol™ Capillary GC Columns
- Product series: Watercol™ capillary GC columns
- Column: Watercol™ 1910
- USP Code: None
- Phase: Non-bonded; 1,11-Di(3-hydroxyethylimidazolium) 3,6,9-trioxaundecane trifluoromethanesulfonate
- Temperature limits: 30 °C to 180 °C (isothermal or programmed)
- Available column format: 30 m × 0.25 mm I.D., 0.20 µm
- Available column format: 30 m × 0.32 mm I.D., 0.26 µm
- Water Kovats Retention Index (KRI) reference for descriptive number: 1910 at 100 °C isothermal oven temperature
Application and usage
- Pharmaceutical moisture determination (ibuprofen): Water is measured in ibuprofen by preparing a solution in acetone and analyzing it on a Watercol™ 1910 column with TCD detection under a temperature program.
- Petrochemical moisture determination (gasoline): GC moisture results are obtained from small sample sizes, including less than 2 mL gasoline, using Watercol™ columns for water measurement in fuel matrices.
- Environmental and other complex matrices with volatile organic compounds: Watercol™ 1910 separates water from volatile organic compounds, supporting moisture analysis when water is present alongside multiple volatiles in complex samples.
- Water as the analyte (water standards in ethanol): Water is quantified using prepared standards such as 0.05% (v/v) water in ethanol, and calibration is demonstrated across 0.01 to 0.5% (v/v) water in ethanol using TCD detection.
- Water as the analyte in mixed analyte sets (small polar analytes in acetone): Water is analyzed as one component within a multi-analyte mixture prepared in acetone, alongside compounds including n-tridecane, 2-octanone, 1-heptanol, 1-octanol, and naphthalene, using TCD detection.
- Water in multi solvent mixtures (chemical solvent screening): Water is measured in a 60 component solvent mixture (each solvent at 0.2% (v/v) and water at 0.3% (v/v) in pentane) using a setup with two identical Watercol™ 1910 columns installed in the same inlet and routed to separate detectors (FID and TCD).
- Water as the injection solvent (solvent mixes in water): Volatile solvent components in water are analyzed with water serving as the injection solvent, demonstrated with an 8 component solvent mix in water that includes acetone, methylene chloride, alcohols, and 1,4-dioxane, using TCD detection and a temperature program.
- Alcohol mixture screening (C1 to C6 alcohol mix): Water impurity is monitored in a C1 to C6 alcohol mix using MSD detection (m/z = 18 to 500), where water appears alongside alcohol components and other listed compounds in the mixture.
- Food and beverage (fusel alcohols in tequila): Aroma fusel alcohols are analyzed in neat tequila using two identical Watercol™ 1910 columns installed in the same inlet and connected to separate detectors (FID and TCD), with water reported among the resolved components as part of the chromatographic profile.
- Detector selection in practice (method setup): Watercol™ column workflows can use multiple detector configurations depending on the measurement, including TCD for water measurement, paired FID and TCD for complex solvent mixes, and MSD for monitoring water impurity in alcohol mixtures; VUV and BID are also suitable detector options for water analysis.
List of products under Watercol™ Capillary GC Columns
| Product | Dimensions | Film Thickness | Cat. No. |
|---|---|---|---|
| Watercol™ 1910 capillary GC column | 30 m × 0.25 mm I.D. | 0.20 µm | 29711-U |
| Watercol™ 1910 capillary GC column | 30 m × 0.32 mm I.D. | 0.26 µm | 29714-U |