How to Extract RNA: Step-by-Step Protocol for Thai University and Hospital Labs
12 min read••By Chemical Express Thailand

Failed RT-qPCR from degraded RNA, phenol carryover, or salt contamination wastes samples and delays results. A single RNase exposure or wrong buffer ratio can destroy a batch before you even reach the thermocycler. This RNA extraction protocol step by step gives you the exact procedure, QC targets, and troubleshooting fixes to produce intact, inhibitor-free RNA ready for RT-qPCR, RNA-seq, or clinical expression assays.
Why This RNA Extraction Protocol Step by Step Matters
RNA is far less stable than DNA. RNases are everywhere: on skin, benchtop surfaces, and in poorly stored reagents. One lapse in technique and you lose your sample entirely, or worse, you generate unreliable data without realising it.
Use this protocol whenever you need consistent, high-purity RNA for RT-qPCR, RNA-seq, transcriptomics screens, or clinical assays where RNase risk is high. Understanding the difference between RNA and DNA extraction principles and steps helps you appreciate why RNA workflows demand stricter nuclease control at every stage.
Target quality metrics before downstream use:
| Quality Metric | RT-qPCR Target | RNA-seq Target |
|---|---|---|
| A260/280 | 1.9 to 2.1 | 1.9 to 2.1 |
| A260/230 | Above 1.8 | Above 1.8 |
| RIN | Above 7 | Above 8 |
| DNA contamination (no-RT control) | Absent or negligible | Absent |
Which extraction method fits your sample type?
- Highest yield from fibrous or lipid-rich tissues
- Tolerates small and degraded samples
- Lower cost per prep
- Requires fume hood; not ideal for high-throughput clinical labs
- Fast, reproducible, and scalable
- Suitable for cells, blood, and swabs
- Supports on-column DNase treatment
- Best for routine lab workflows and clinical settings
- Automatable and high-throughput
- Gentle on fragile RNA species
- Good for low-volume or low-input samples
- Higher reagent cost per sample
What You Need: Equipment, Reagents, and RNase Control
Equipment checklist
Gather everything before you begin. Stopping mid-protocol to locate equipment introduces delays that degrade RNA.
- Microcentrifuge capable of 12,000 to 16,000 x g
- Bead mill or rotor-stator homogenizer for solid tissues
- Calibrated pipettes with RNase-free filter tips
- Magnetic rack (if using bead-based isolation)
- Vortex mixer
- Biosafety cabinet for BSL-2 or clinical samples
- Ice bucket and heat block adjustable from 37 to 60 C
- Nanodrop or spectrophotometer; Bioanalyzer or TapeStation for RIN assessment
Reagents and consumables
- Guanidine thiocyanate lysis buffer with 1% beta-mercaptoethanol added fresh before use
- TRIzol or equivalent phenol-based reagent (organic extraction path only)
- Chloroform (organic extraction path only)
- 70% ethanol prepared with RNase-free water
- DNase I with manufacturer-supplied reaction buffer
- RNase inhibitor to protect RNA during downstream reactions
- Certified RNase-free water for all dilutions and elutions
- Spike-in RNA control (e.g., ERCC mix) at manufacturer-recommended dilution for normalization
- RNase-free microtubes, low-bind tips, and collection tubes
- Silica spin columns or magnetic beads with binding and wash buffers
- Phase lock gel tubes (phenol path, optional but recommended)
- PPE: lab coat, nitrile gloves, eye protection; dedicated phenol waste containers
Sigma-Aldrich's RNA Purification portfolio under Nucleic Acid Purification covers DNase I, RNase inhibitors, certified RNase-free water, and spin column kits. These reagents are available through Chemical Express Thailand for Thai university and hospital procurement.
Prepare Samples and Lyse Cells or Tissue Quickly
Speed and cold temperatures are your two best defenses at this stage. Every second between tissue disruption and nuclease inactivation is an opportunity for RNA degradation.
- Prepare your input material. For tissue, weigh 10 to 50 mg per tube. For cell pellets, use 1 to 5 million cells. Record the exact input mass or cell count for yield calculations.
- Add lysis reagent immediately. Use 1 ml TRIzol per 50 to 100 mg tissue, or 350 to 600 microliters guanidine thiocyanate lysis buffer per up to 1 million cells.
- Add beta-mercaptoethanol fresh. Mix beta-mercaptoethanol into lysis buffer at 1% v/v immediately before use, or add DTT to a final concentration of 10 to 20 mM. This step inactivates RNases in the lysate.
- Homogenize until clear. Run the bead mill or rotor-stator until no visible particulates remain. Avoid vigorous vortexing of viscous lysates; it generates heat and can shear RNA in some tissue types.
- Mix the lysate. Pipette 10 to 15 times to ensure complete cell disruption. For column-based methods, centrifuge at 10,000 x g for 3 minutes to pellet debris before loading.
- Incubate at room temperature for 5 minutes. This allows the chaotropic agent to fully inactivate nucleases. If processing is delayed beyond 15 minutes, hold lysates on ice.
Separate Phases and Bind RNA to Column or Beads
Phenol-chloroform phase separation
- Add chloroform. Add 0.2 ml chloroform per 1 ml TRIzol used. Cap the tube securely.
- Shake and incubate. Shake by hand for 15 seconds. Incubate at room temperature for 3 minutes to allow phase partitioning.
- Centrifuge. Spin at 12,000 x g for 15 minutes at 4 C. Three phases will form: a lower red phenol-chloroform layer, a white interphase, and a clear upper aqueous layer containing the RNA.
- Transfer the aqueous phase. Carefully remove the upper aqueous phase with a pipette, avoiding the interphase. Phase lock gel tubes improve recovery and reduce interphase contamination.
Column cleanup after TRIzol or direct column path
- Prepare the binding mix. Add 1 volume of 70% ethanol to the recovered aqueous phase (TRIzol path) or to the cleared lysate (direct column path). Mix by inversion 5 times.
- Load the column. Transfer up to 700 microliters per load to the silica spin column. Centrifuge 30 to 60 seconds at 10,000 to 12,000 x g. Discard flow-through. Repeat until all sample is loaded.
Magnetic bead path
- Add binding buffer and beads. Follow the kit-specified ratio; typically 1.5 to 2.0 volumes of binding buffer relative to lysate volume, plus the recommended bead volume.
- Incubate with mixing. Mix for 5 minutes at room temperature to allow RNA to bind the bead surface.
- Capture beads. Place the tube on the magnetic rack for 2 minutes until the solution clears. Remove and discard the supernatant carefully without disturbing the bead pellet.
| Step | Column Path Volume | Bead Path Volume |
|---|---|---|
| Ethanol addition | 1 volume (relative to aqueous phase) | Per kit binding buffer ratio |
| Load per spin | Up to 700 microliters | Not applicable |
| Binding incubation | 30 to 60 seconds centrifugation | 5 minutes at room temperature |
| Phase separation | Not applicable | 2 minutes on magnet |
Wash, DNase Treat, and Elute Intact RNA
Washing the column or beads
- Apply wash buffer. Add 500 microliters of ethanol-containing wash buffer to the column or resuspend beads in the equivalent wash volume per the kit protocol.
- Centrifuge or capture. For columns, spin 30 to 60 seconds and discard flow-through. For beads, place on magnet, remove supernatant. Repeat for a total of 2 to 3 wash cycles.
- Dry spin (columns only). After the final wash, perform a 1 minute dry spin at maximum speed to remove residual ethanol. Ethanol carryover inhibits downstream enzymes and distorts A260/230 readings.
On-column DNase treatment
- Prepare the DNase mix. Combine 10 microliters DNase I with 70 microliters reaction buffer (80 microliters total per column). Mix gently; do not vortex the enzyme.
- Apply to the membrane. Pipette the mix directly onto the silica membrane. Incubate 15 minutes at room temperature.
- Continue washing. Add wash buffer and centrifuge as normal to remove DNase and digested DNA before elution.
Post-elution DNase cleanup (alternative)
- Add DNase reaction mix to eluted RNA. Follow manufacturer volumes for DNase I and the supplied buffer. Incubate 15 to 20 minutes at room temperature.
- Purify to remove DNase. Use a 2.5x volume magnetic bead binding ratio, or add ethanol and rebind RNA to a spin column for a second cleanup step.
Elution and QC
- Pre-warm elution water. Heat RNase-free water to 60 C in the heat block. This improves RNA release from the silica membrane by 10 to 20%.
- Elute. Apply 30 to 50 microliters of pre-warmed RNase-free water to the membrane or bead pellet. Incubate 1 minute, then centrifuge or capture and collect the eluate.
- Optional second elution. Add a second 30 microliter aliquot to capture remaining RNA. A second elution typically increases total yield by 10 to 20%.
- Measure purity. Read A260/280 and A260/230 on a nanodrop. Target A260/280 of 1.9 to 2.1 and A260/230 above 1.8.
- Assess integrity. Run a 1% agarose gel or use a Bioanalyzer or TapeStation. Target RIN above 7 for RT-qPCR and above 8 for RNA-seq.
- Store RNA immediately. Hold on ice during setup. Aliquot to avoid freeze-thaw cycles and freeze at minus 80 C.
Once you have confirmed RNA purity and integrity, your extract is ready for reverse transcription. For a detailed explanation of what happens next, see this guide on PCR principles and steps for Thai researchers, which covers RT-qPCR setup in practical terms.
Sigma-Aldrich's Molecular Biology and Functional Genomics portfolio, available through Chemical Express Thailand, includes RNA purification kits, certified DNase I, RNase inhibitors, and NGS library preparation reagents to carry your RNA through to sequencing.
Tips, QC, and Safety Notes for Thai Lab Workflows
Quick tips for better RNA yields and data quality
- Pre-chill pestles and homogenization tubes on ice or in liquid nitrogen before tissue processing.
- Use phase lock gel tubes with TRIzol to improve aqueous phase recovery and reduce interphase contamination.
- For low-input samples (under 100,000 cells), add linear acrylamide or glycogen carrier at 5 to 20 micrograms per tube to improve pellet visibility and bead recovery.
- Avoid over-drying the silica membrane; 1 minute dry spin is enough. Over-drying reduces elution efficiency.
- Pre-warm elution water to 60 C for higher yield from silica columns.
- Use low-bind, RNase-free plasticware throughout. Standard polypropylene tubes can cause RNA adsorption at low concentrations.
- Calculate RNA concentration using A260: 1 A260 unit equals 40 micrograms per milliliter for single-stranded RNA.
- Always include a no-RT control in your RT-qPCR run to confirm DNA contamination is absent.
- Store DNase I in small single-use aliquots at minus 20 C. Avoid repeated freeze-thaw cycles.
- Discard lysis buffer with added beta-mercaptoethanol at the end of the working day. Do not store it.
- Keep ethanol-containing wash buffers tightly capped; evaporation lowers effective concentration and reduces washing efficiency.
- Store RNase inhibitor at minus 20 C in aliquots. Limit freeze-thaw to preserve activity.
Troubleshooting Common RNA Extraction Issues
| Problem | Likely Cause | Fix |
|---|---|---|
| Low yield from tissue or blood | Insufficient lysis reagent volume, incomplete homogenization, or over-dried membrane | Use at least 10 volumes lysis buffer per wet tissue volume; confirm full homogenization; limit dry spin to 1 minute; add a second elution step |
| Degraded RNA, low RIN, or smearing on gel | RNase contamination on bench, tips, or from poorly stored reagents; slow processing at room temperature | Decontaminate all surfaces and equipment; change gloves frequently; add beta-mercaptoethanol fresh; keep samples on ice between steps; replace suspect reagents |
| Genomic DNA detected by no-RT control | Incomplete DNase treatment or DNase I inactivity from expired stock | Repeat on-column or post-elution DNase treatment; verify DNase I activity with a control digestion; use fresh aliquots from minus 20 C storage |
| Low A260/230 (phenol or chaotrope carryover) | Insufficient washing, aqueous phase contaminated with interphase during TRIzol step, or residual guanidinium | Add an extra wash cycle; use phase lock gel tubes; ensure column is not overloaded; perform a second column cleanup with fresh ethanol wash |
| Column clogging with viscous lysate | Too much starting material, incomplete debris removal, or high DNA content in sample | Reduce input to 1 to 2 million cells or 10 to 20 mg tissue; pre-centrifuge lysate 10,000 x g for 3 minutes to remove debris; dilute lysate 1:1 with lysis buffer before loading |
| Bead carryover elevating A260 or inhibiting enzymes | Insufficient magnet capture time or pipetting too close to bead pellet during supernatant removal | Extend magnet incubation to 3 to 5 minutes; leave 5 to 10 microliters of supernatant behind when aspirating; wash beads with an additional low-salt wash step |
Producing Reliable RNA: Final Checks Before Downstream Use
Tight RNase control, correct reagent ratios, thorough DNase treatment, and careful elution together give Thai university and hospital labs a reproducible path to intact, inhibitor-free RNA. The quality metrics are non-negotiable: confirm A260/280, A260/230, and RIN before committing RNA to any sensitive assay.
If purity or integrity falls short, the troubleshooting table above points you to a corrective action without having to repeat the full extraction from scratch. Small adjustments, such as an extra wash, a fresh DNase aliquot, or a slower magnet capture, typically resolve the most common problems.
Chemical Express Thailand stocks Sigma-Aldrich RNA purification reagents, DNase I, RNase inhibitors, and the full Molecular Biology and Functional Genomics product range. Contact us for product availability, pricing, and technical support tailored to Thai lab procurement cycles.
Frequently Asked Questions
Recommended Products
All products below are available through Chemical Express Thailand. Submit an inquiry for pricing, availability, or technical guidance.
Recommended Products Available at Chemical Express
We deliver a wide range of Nucleic Acid Extraction products from Merck, MedChemExpress (MCE) and TCI and other international brands across Thailand. For any inquiry or purchase, fill out our Inquiry Form or chat with us instantly on Line.